58 Appendices
Calibration and Wiring Notes
Note 1 – Calibration Functions
The following pins are calibrated in the Base Maps
with the function and
parameters as mentioned in the table.
M400 Pin Sea-Doo Pin Function
Parameters
Aux1
A18 not used 9: Lambda Heater
Aux2
A01 B29 101: Fuel Pump Delay 3.0
Polarity 0
Output Mode 0
Aux3
A23 A13,B18 (2004)
3: Aux Table
PWM/Switched 0
Output Mode 0
Polarity 0
Frequency 200
Minimum Duty Cycle 0
Maximum Duty Cycle 100
Hysteresis 0
Aux3 A23 A13,B18 (2006)
0: Off
Aux3
A23 A13,B18 (2007)
107: Driver
Warning
Hold Time 0
Delay to On Time 0.0
Include Diag Errors 0
Logic Polarity 0
Output Mode 0
Power Hold 0
On Alert 1
Aux4
A24 B31 115: Status
Selection 40
Logic Polarity 0
Output Mode 0
Flash 0
Flash Rate 0.0
Aux5
A31 A36 8: Idle Stepper
Max Step Rate 200
Polarity 0
Aux6
A32 A35 0: Off
Aux7
A33 A38 0: Off
MoTeC
with the function and
Parameters
Polarity 0
Output Mode 0
PWM/Switched 0
Output Mode 0
Polarity 0
Frequency 200
Minimum Duty Cycle 0
Maximum Duty Cycle 100
Hysteresis 0
Hold Time 0
Delay to On Time 0.0
Include Diag Errors 0
Logic Polarity 0
Output Mode 0
Power Hold 0
On Alert 1
Selection 40
Logic Polarity 0
Output Mode 0
Flash Rate 0.0
Max Step Rate 200
Polarity 0